Hi John
I really appreciate your response and indeed I also initially suspected stability of pots/Scarlet, although they feel mechanically very stable, but realising this could lead to error ensured no movement between measurements and cal etc. I repeated the tests to include calibration each...
Here's a thought especially considering that 0.1% resistors aren't cheap and values <100R are rare, use 10 x 1% in parallel and create various known loads to check the accuracy between 0R - 100R.
If my memory serves me correctly, even if every single resistor was at the max 1%, the maximum...
You can find the guide here: impedance measurement
And that's the catch, the measurement R & DUT R are both at 0.1% 100R and it's out by more than 0.2R...
Hi All
New to REW so please forgive me for a while ;-)
So this weekend I created the REW impedance measuring jig including a 0.1% 100R resistor to be used with my two channel Focusrite Scarlett 2i2 (headphone out) and it was a reasonable success, however I have a couple of...
Thanks John, much appreciated, will give it a try.
I note that ARTA has a way to reduce the levels when merging far and near field, can REW accomplish similar?
Cheers
Lea
Trying to follow this guide...http://audiojudgement.com/loudspeaker-measurements-part-2/
So I now wonder how one can scale and merge using REW?
Uhm, I wonder: The Scale FR Peak control re-scales the impulse response to achieve a desired maximum SPL figure in the corresponding frequency...
Sorry I don't follow. I simply discovered the IR window which allows IR export between two precise points in time, which I believe is what's required for VituixCAD
Ah Ha!
Think I've found it thanks to 3ll3d00d.
https://1drv.ms/u/s!AgmKo7c0CB2xjE8-6WAO5ytsTE-l
So we can set the the IR Left and Right windows appropriately, left just before the initial impulse and right just before the first reflection, then export all.
Getting there :-)
Edit - how did...
Hi All
So I'm finally setup and measuring my speakers...BUT every guide I can find is for ARTA and maybe its just me but I'm hoping to use REW (free & has additional advantages of all the room/dsp etc built-in for later use).
I have test IRs which I'd like to export, however in ARTA the...
Hi All
Firstly, what an amazing piece of software, THANK YOU John.
Precis:
Can REW be used as an alternative to ARTA for Impulse Response measurements? And how?
Forgive me but ARTA's manual is complex and I'm a nuub (although an ex-Electronics Eng.), REW's manual is AWESOME but I'm looking...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.