Recent content by LeaUK

  1. LeaUK

    REW - Impedance measurement - accuracy?

    Hi John I really appreciate your response and indeed I also initially suspected stability of pots/Scarlet, although they feel mechanically very stable, but realising this could lead to error ensured no movement between measurements and cal etc. I repeated the tests to include calibration each...
  2. LeaUK

    REW - Impedance measurement - accuracy?

    Here's a thought especially considering that 0.1% resistors aren't cheap and values <100R are rare, use 10 x 1% in parallel and create various known loads to check the accuracy between 0R - 100R. If my memory serves me correctly, even if every single resistor was at the max 1%, the maximum...
  3. LeaUK

    REW - Impedance measurement - accuracy?

    You can find the guide here: impedance measurement And that's the catch, the measurement R & DUT R are both at 0.1% 100R and it's out by more than 0.2R...
  4. LeaUK

    REW - Impedance measurement - accuracy?

    Hi All New to REW so please forgive me for a while ;-) So this weekend I created the REW impedance measuring jig including a 0.1% 100R resistor to be used with my two channel Focusrite Scarlett 2i2 (headphone out) and it was a reasonable success, however I have a couple of...
  5. LeaUK

    Export IR response...?

    Thanks John, what else could one want! Awesome! Thank you Lea
  6. LeaUK

    Export IR response...?

    Thanks John, much appreciated, will give it a try. I note that ARTA has a way to reduce the levels when merging far and near field, can REW accomplish similar? Cheers Lea
  7. LeaUK

    Export IR response...?

    Trying to follow this guide...http://audiojudgement.com/loudspeaker-measurements-part-2/ So I now wonder how one can scale and merge using REW? Uhm, I wonder: The Scale FR Peak control re-scales the impulse response to achieve a desired maximum SPL figure in the corresponding frequency...
  8. LeaUK

    Export IR response...?

    Sorry I don't follow. I simply discovered the IR window which allows IR export between two precise points in time, which I believe is what's required for VituixCAD
  9. LeaUK

    Export IR response...?

    Ah Ha! Think I've found it thanks to 3ll3d00d. https://1drv.ms/u/s!AgmKo7c0CB2xjE8-6WAO5ytsTE-l So we can set the the IR Left and Right windows appropriately, left just before the initial impulse and right just before the first reflection, then export all. Getting there :-) Edit - how did...
  10. LeaUK

    Export IR response...?

    Hi All So I'm finally setup and measuring my speakers...BUT every guide I can find is for ARTA and maybe its just me but I'm hoping to use REW (free & has additional advantages of all the room/dsp etc built-in for later use). I have test IRs which I'd like to export, however in ARTA the...
  11. LeaUK

    REW - SPL uncalibrated message?

    Thanks Wayne, that's really useful. Using non-USB so will enter 75 dB, perfect, cheers.
  12. LeaUK

    REW - SPL uncalibrated message?

    Hi Using a Sonar Works mic with calibration file, why does REW ask for SPL calibration? Lea
  13. LeaUK

    REW for Speaker Measurement?

    Hi All Firstly, what an amazing piece of software, THANK YOU John. Precis: Can REW be used as an alternative to ARTA for Impulse Response measurements? And how? Forgive me but ARTA's manual is complex and I'm a nuub (although an ex-Electronics Eng.), REW's manual is AWESOME but I'm looking...
Top Bottom