Recent content by atharva

  1. A

    Weird loopback response from a tube amp

    When you said the scale was unforgiving did you mean that the response wasn't all that bad?
  2. A

    Weird loopback response from a tube amp

    Thanks John.. If the scale is unforgiving does it mean one can use such an amp for measurement if one had to? I mean if one used a tube amp for listening then I suppose I should use the same amp for measurement.
  3. A

    Weird loopback response from a tube amp

    Hi, I've been using a solid state amp with UR22C for loudspeaker measurements. I decided to try to see how a tube amp would work. While doing the loopback calibration I'm seeing a very weird response. I've tried both channels. It appears that there is mains (50Hz) distortion and harmonics. I...
  4. A

    Soundcard calibration look ok?

    John, you're observation is spot on. I should've caugtht that! Moving the cable away from the power cable improved it a lot. I reduced the buffer size to 64K. Thought I'll post some screenshots in case it helps others. Also see the bottom screenshot where disconnecting the timing reference made...
  5. A

    Soundcard calibration look ok?

    Hi, I did my first sound card calibration for the UR22C audio interface using a dual-channel setup with the output looped back from the amp to the input. My settings are.. Sample rate: 96K Buffer : 128K (in preferences) Sweep Length : 512K (in measurement window) 1. Are those wiggles ok? The...
  6. A

    "Timing offset" warning when calibrating REW with UR22C and Amp

    Thanks John.. The steps in the preferences screen said to create a loopback and I just wanted to confirm that when doing this with a voltage divider circuit and an amp that the way to create the loopback is to short the Rsense. Thanks for confirming that. My calibration measurement distortion...
  7. A

    "Timing offset" warning when calibrating REW with UR22C and Amp

    Thanks for the clarification John. I tried simulating the error when uping the sample rate to 192K. But I just couldn't. The offset just changed from 0.14 to 0.16. I am positive that I got an error saying the offset is too large. I think it was something like 1.16. Regarding calibration I...
  8. A

    "Timing offset" warning when calibrating REW with UR22C and Amp

    First, a huge thanks to John for making this wonderful software available to us. This is my first time doing this. I've got the UR22C connected to a Macbook Pro M1 and am using a NAD class AB amp with a voltage divider as in the following thread except with 47K and 22K resistors and a 9.6R...
Top Bottom