    REW5.20.4 HI PASS Not working..

    I did made input and output selections on the REW soundcard preferences ,but some times,it is not show on the measure page.i did again. and you right,5.20.3 doesn't make the validity check, that doesn't mean the result is valid. i think someting wrong with this soundcard,not just DC .
  2. 2631378999

    REW5.20.4 HI PASS Not working..

    now,im sure about some thing: (1)5.20.3 impedance calibration and measurement is working, (2)5.20.4 fail on impedance short calibration,i don't know why. (3)“hi pass” is working,but level meter display on measure page looks wrong. And have some suggestions. LPF and HPF should be added and the...
  3. 2631378999

    REW5.20.4 HI PASS Not working..

    i just try to use 5.20.3, impedance can be calibrate and measurement.input level meter on measure page looks same.i don't know why it works,let me try more and tell you
  4. 2631378999

    REW5.20.4 HI PASS Not working..

    I did all,input hi pass checked on the prefences,input is line in L,reference input is line in R,out put is line out L.
  5. 2631378999

    REW5.20.4 HI PASS Not working..

    Hi John~ Today i trying to use a soundcard to measurement impedance,but looks like hi pass not working on measurement(but works on levels),so i can"t do imp cal. It will be great if hi pass works again;)
  6. 2631378999

    New feature of REW

    And,rew can be add a“microphone amplifier gain seting”,when microphone amplifier change gain will be no longer need recalibrate 94db spl。 And,if rew can just input microphone sensitive data(like 12mV/Pa,or -40dBV/Pa),will be very nice,no “94db spl calibration”need。
  7. 2631378999

    New feature of REW

    And,it will be helpful if rew can save microphone sensitive calibration data to file,like i have 2 microphones,if i switch microphone,rew need recalibrate 94db spl。
  8. 2631378999

    New feature of REW

    Hi,do you have any plan to add full iso3382 measurement ?Something very useful like STI。 :rubeyes: And,if rew have “limit curves”(can be modified) will be very helpful to tell if loudspeaker system fit hifi standard like IEC60581。
  9. 2631378999

    trying import mic cal data to rew520beta47

    and just show you soundcheck“s way to import data,may help?
  10. 2631378999

    trying import mic cal data to rew520beta47

    really need rew to read the soundcheck“s data。some times,the sc data freq is high to low, (the rew data freq is low to high),i think that"s why rew can not read soundcheck data
  11. 2631378999

    rew520 beta47 captured bug

    the captured only show the last measurement..
  12. 2631378999

    rew5.20beta45 Short circuit cal not working

    new error REW V5.20 Beta 45 running JRE 1.8.0_241 64-bit on Windows 10, en, windows-1252 Message: java.lang.ArrayIndexOutOfBoundsException: 524288 Stack Trace: 524288 roomeqwizard.SweepAnalyser.A(y:2435) roomeqwizard.QD.A(y:479) roomeqwizard.QD.A(y:2117)...
  13. 2631378999

    rew5.20beta45 Short circuit cal not working

    stop at 99%
  14. 2631378999

    Limit design for rew

    How to know the speaker system is hifi? Limit will help you judge. Limit can be added, for example (frequency response, thd, impedance). Limit tool will help you to make limit with measurement results。 In the graphic display interface, it should show pass or fail.. Limit should have at least 2...