impulse response

  1. S

    Measurement Imulse Graph Looks Weird, Need Help.

    I use UMIK-1 to measure the sweep frequency response of my speaker in my listening postion. I found out the impulse graph looks weird. Is it normal or maybe my UMIK-1 is broken? The SPL graph look normal though. Thanks for any help !
  2. P

    Setting to disable automatic determination of Ref in IR plots

    Hello REW forum, New REW migrant in loudspeaker design here. I noticed that the Ref point is automatically matched to the time of the IR peak at each new measurement. While I have seen that the windows of L and R relative to Ref can be manually overridden, I have not found a UI control to...
  3. S

    REW: export smoothed impulse responses (.wav), but "measured" and not "minimum phase"...

    Hi all!... I wanted to ask a question, but I think that some background could be of help, because I'm not using REW for the usual things (I'm using it for music production)... I learned how to use it when I had to measure my treated room, but then I've used it to create some impulse responses...
  4. A

    Pseudo anechoic speaker measurements.

    I would like to approximate an anechoic speaker measurement from 200hz to 20khz in an 11'x15' room. To do this I assume I would need to do gated measurements. Within REW, I believe gating is controlled via the IR panel which I have never used. Could someone explain what a good set of values for...
  5. B

    Will REW created correction impulse response fix the room reverb?

    Hello, I'd like to use REW to create an impulse response for my Equalizer APO convolver with simple 2.0 speakers setup. I'm on the verge of buying UMIK-1, but first I have to be sure it will also compensate the reverb I've got in the room. Would be grateful for a clarification!
  6. F

    External signal for measuring reverbation time in REW

    Hello, I´m quite newbie here, so please take that in account. I recently bought UMIK-1 measuring microphone. I´m interested especially in measuring reverbation time of bigger rooms, RT60. Yesterday I tried to measure RT60 using sweep sound implemented in REW. However at school, we used gun...
  7. A

    feature request : save the average of responses

    When i load a couple of impulse responses, in the All SPL tab, there is an "average the responses" button. no average buttons in any other tabs though, maybe that would be cool. anyway. now what would be very useful, at least to me, would be the ability to save that average impulse response...