Recent content by Takafumi Ueno

  1. T

    Version

    The problem has been solved. The cause of trouble is the default setting of the headphone jack sound system of LAVIE. The default setting of the headphone jack of LAVIE is not flat, although that of T551 is flat. The following is the frequency response using REW5.20. The frequency response is...
  2. T

    Version

    The loopback test indicates that the frequency response of LAVIE does not seem to be flat. It is a very curious response. I don't know why.
  3. T

    Version

    Attached are the files. 1) 20210528_REW519onT551_0 Correct data 2) 20210528_REW520onLAVIE_0 Not correct data v520 beta7 on LAVIE I'm doing the loopback test on LAVIE. There is something strange. Best regards, Takafumi Ueno
  4. T

    Version

    The input device is as follows. Mic: ECM8000 Preamp: EMU0404 (to USB) The same device is used for both LAVIE (version5.20) and T551 (version5.19) Best regards, Takafumi Ueno
  5. T

    Version

    I use REW v5.19 on Toshiba T551(2011 old PC). The measure frequency response looks OK. It matches well with TrueRTA Quick Sweep. Now I download v5.20 and tested pn NEC LAVIE (2018 new PC). The measured response is not correct. I dlownloaded the older version 5.19 from the Home page, but in...