Just downloaded the latest version that now has the Linkwitz Transform as a filter option and loving it! This makes my workflow even easier!
I did notice that the paramters for the LWT filter get overwritten if you ask REW to match the target curve, where I would prefer for it to stay fixed...
Got it. I opted for the Oehlbach because a friend endorsed it. They are expensive, but i spent so much time on this, i wish i bought the expensive cable right away. I had to make some changes to my setup to work with the 3m cable (i used to have the 5m, but it gave nothing but problems as you...
Okay - i made an experimental setup so i could measure with the UMIK-2 and the original short cable. It compromises my setup a bit, but good enough for testing.
With the short USBC cable, i get consistent measurements without the drop. The measurement below is without any filters active. The...
I just made 2 audio recordings using the Umik-2. One with the original USBC cable that comes with the Umik-2. Another one with a longer USBC cable i use for measurements. The recording made with the longer USBC cable has static & tics. It is very audible when I play back the recording. The...
Thank you John - i'll do some tests with cables etc. The cable is obvisouly different from the Umik-1 as it's a USB-C connection cable. I purchased an extra long one, as the one that comes with the Umik-2 is too short for decent measurement of my speakers in the setup i use.
I think i tried...
Thank you, and yes the 1st episode was better. But I cannot trust my measurement system and that is a big problem of course. I use REW to analyse the design of my speaker. I design these in FreeCAD and get them professionally printed. This is very costly. I need to ensure that the measurements...
Hello,
i have reduced the buffer-sizes, set measurement to -3 dBFS and used the acoustic ref option. There is no difference. I was not able to produce consistent measurements. See MDAT file attached and example below. A Umik-1 measures fine btw.
Stefan
I have had the Mic checked by the supplier. It seemed to measure fine on their setup. (their setup is REW on windows, I run REW on my Mac).
I did some more tests this morning and I think i found the root cause. It looks like there is a correlation with the length (end frequentie) of the sweep...