Recent content by Rob Greer

  1. R

    Inconsistent Impulse Measurements

    I looked at the waveforms for 3 successive measurements and the waveforms looked the same. I'm making the measurements from a Win 10 OS machine. And it's the same device I used to previously make successful measurements. SOLVED: Removing the active USB cable between umik and computer fixed it...
  2. R

    Inconsistent Impulse Measurements

    Thanks so much for taking a look. I saw that I had the timing reference turned off right after I made my post, but enabling that again (and it’s always enabled except for that test) doesn’t change the behavior. As for the sub auto on, before I run the tests I check the levels and that sends a...
  3. R

    Inconsistent Impulse Measurements

    I'm using REW 5.20 Beta 41 and when I measure my 4 SVS PB16s individually I'm getting inconsistent impulse measurements. For example, if I run the same measurement 5x on the same sub with each measurement following the next, I'm lucky if 3 of 5 measurements match. Sometimes only 2 match. And now...