Thank you, that seems to take care of the issue. I guess I never really noticed the "k" in the buffer settings in REW. Makes sense that 512k samples at 48kHz SR take a while to flush.
However, I do wonder why sometimes the capturing already started after just two passes?
I also ran into...
Here's some testing with the ADI 2/4, measurement taken with XLR loopback from channel 1 output to channel 1 input:
Behavior is the same for THD vs. Level and THD vs. Frequency
I've recorded two short-ish screen captures of the process (please note the spaces in the link as I am not yet...
this happens with multiple tested devices (several audio interfaces of varying quality such as RME ADI 2/4 pro, arturia audiofuse, zoom u44). Playback and recording device is the same (audio interface).
This even happens with direct loopback (line out -> cable to line input), so there is no...
When using the stepped sine mode, the software sometimes does dozens (I counted) repetitions before actually starting with the averaging.
Sometimes it does just one or two passes of capturing the signal before starting the averaging and moving onto the next step, but sometimes it takes 20 or...
Hi,
many of us work with the dark mode in the software, but for publishing/sharing measurement results, using the light theme is usually preferred. I know it's relatively quick to swap between both modes, but I think an option in the image dialog to use light theme for export would be very handy.