Recent content by Midiman

  1. M

    Scale limits in impedance measurement

    Thanks for all the helpful answers !!!!
  2. M

    Scale limits in impedance measurement

    Aaaaaaaah.... I found it! (It is in the 'Controls' submenu) Ok.... that seems to work for my purpose. And sure, I am aware of the impedance behaviour of transformers. Still, it is a kind of 'fingerprint' of the transformer and it might make sense to linearize that impedance with some...
  3. M

    Scale limits in impedance measurement

    Doesn't work. When measuring Impedance it goes max. 1000 Ohm on the Y axis. Also entering it manually doesn't work. It jumps back to '1000.'
  4. M

    Scale limits in impedance measurement

    Select log impedance axis in the graph controls. I only have [Frequency axis log/linear] in the graph control. That selects log or linear X frequency axis but doesn't affect the Y axis. Am I missing something?
  5. M

    Scale limits in impedance measurement

    I have a similar question. I was trying to measure the input impedance of a 1:1+1 audio line level transformer. I can see a curve at the left side and the cursor shows values between 5k and ~ 200 k but the scale of the Y axis only goes to 1000 ohm so I never actually see the curve. Is there a...
  6. M

    Microphone placement for measurements

    Ok, thanks, I'll check it out.
  7. M

    Microphone placement for measurements

    In this context I have a REW beginner's question. In other measurement software it is quite common to measure several times at slighlty different positions and then average those measurements. This greatly cancels out (micro-) local effects for the benefit of making the general response more...
Back
Top