Hi John,
Thanks for the quick solution, missed to see thise options.
I saved it as a preset to recall later but one question.
Cant we set it as a default setting for all new measurement? seems to change on every measurement.
Tks Mallick
I am doing the sweep to measure the freq response of my speaker which is 2way system, but my freq is limited is 100Hz and not below, I tried the following.
1. Mic calibration file installed in REW
2. Tascam 366 calibrated and found linear
3. Both loopback and timing levels are ok
4. SPL level...