Thanks both!! I have always set the timing window based on 0-deg and applied to all, so this has probably happened many times and I just hadn't noticed. This time I saw the weird results and panicked. :)
I am measuring raw speaker drivers in a cabinet, taking 0-180 degrees in 20 degree increments. I am following the VituixCAD guidelines and have Left side default width 2ms and Right side default width 5ms. Up until about 120 to 140 degrees everything works fine. In the screenshot below at 100...
The Pro Upgrade to REW allows for multiple mic measurements at a time. But before I spend $100 for the upgrade, I want to make sure it can do what I have in mind for loudspeaker Spinorama measurements. Can I use the Repeated Measurements option with the Multi-input Capture capability?